GLOBE VALVES :
Globe valves are widely used in the pipe lines to regulate fluid flow rate in both on / off and throttling purpose. The location of the valve disc in relation to the valve seat allows or restricts flow. High temperature and pressure resistance graphite packings are used in this kind of valves.
NOVA-MAR Globe Valves are designed as Straight or Angle form , Stop Type or SDNR ( Screw Down Non Return ) with or without spring in GG25,GGG40.3,GSC25 and Rg5.
Applications :
Steam
Hot water
Compressed air
Non-acidic and non-alkali fluids
GATE VALVES :
Gate valves are characterised as having either a rising or a non-rising stem and are produced at NOVA-MAR Valves according to DIN 3204 and DIN 3216 standards. Rising stem provides a visual indication of valve position. Non-rising stem gate valves are used where vertical space is limited. Gate valves must be used as fully open or fully closed position where the vibration does not exist in the system. As they are designed as this purpose gate valves are not suited for regulating flow.
NOVA-MAR Gate Valves can be produced with indicator, double threaded stem, draining plug in GG25, GGG40, GGG40.3 and GSC25.
Applications :
Hot and cold water systems
Fuel oil stations
Drinking water and irrigation systems
Fire fighting systems
Pumping stations
Non-acidic gas liquids
CHECK VALVES :
The main task of check valves in the pipe lines is to prevent the possibility of reverse flow of the fluid when the fluid stops. Lift type check valve closes very fast because of the movement of its disc and prevent to reverse flow.With this way, it minimizes the water impacts in the system. They are also known as globe type of check valves and they are installed in the pumping side in the line.
Check valves are used for the following purposes :
- to protect of equipments that can be effected by reverse flow such as flowmeters, strainers and control valves,
- to prevent of flooding,
- to check the pressure alterations,
- to prevent of reverse flow on system shutdown,
- to release of air conditions,
- to prevent of under gravity.
NOVA-MAR Check Valves are available in GG25,GGG40,GGG40.3 and GSC25.
Applications :
Pump stations
Hot and cold water
Non-acidic and non-alkali fluids
Steam
Heating systems
Pressured air
BALL CHECK VALVES :
Ball Check Valve is a valve in which the disc, the movable part to stop the flow, is a circular ball. When pressure is pushed out on the ball, it is moved off its seat allowing fluid to pass through the inlet. When the fluid pressure decreases, the ball slides back into its position on the inlet seat. Ball check valves are only used in liquid systems and can be produced in GG25,GGG40,GGG40.3 or GSC25 at NOVA-MAR Valves.
SWING CHECK VALVE :
Swing Check Valves are used for preventing the reverse flow of fluid in the liquid system.They are especially used in the pumping stations and their task is to stop back flow when the pump is out of service becuase of any reason . In the system, the pressure of the fluid forces the disc to hinge upwords allowing flow through the valve.Reverse flow will cause the disc to shut against the seat and stop the fluid going back down the pipe. When there is no flow in the system, the weight of the flap is responsible for the closure of the valve; in some cases, closure may be supported by the use of a weighted lever. NOVA-MAR Swing Check Valves are Standard or with lever & weight types in GG25, GGG40, GGG40.3 and GSC25.
STORM VALVES :
Storm valves are used in marine applications and they are used on the waste circuits. They allow fluid to flow in one direction. Ductile iron, Bronze or Carbon Steel NOVA-MAR Storm Valves are produced as Straight or Angle Form with or without closing device.
STRAINERS :
Strainers are used for protecting equipments such as meters, pumps, and control valves from the solid particules in the system and installed their side. They have stainless steel filters and inside of filters can be cleant periodically or can be changed with the new one by removing the plugs on the valve.As this reason, there is a plug on the bonnet or bottom of the body depends on the type of strainer.Filter’s location in the valve allows high particulate collecting capacity and minimum pressure loss. Y Type Strainers are used mainly where small amounts of solid particulate are expected and where clean out will be infrequent.
Applications :
Steam
Boiling water
Non-acidic and non-alkali fluids
Pressured air
MUD BOXES :
The function of Mud Boxes are like strainers .The screen is in the form of a basket with a lifting handle so that all particulate captured and retained by the screen can be easily removed for disposal. They are intended for applications where larger amounts of solid particulate are expected and where clean out will be frequent.
FIRE VALVES
SOUNDING COCKS
OTHER FITTINGS & VARIOUS FLANGES
UPCOMING PRODUCTS
* QUICK CLOSING VALVES
* BUTTERFLY VALVES ( DOUBLE FLANGED – WAFER & LUG TYPE)
* BELLOW SEAL VALVES
* PISTON VALVES
* BALL VALVES
* FOOT VALVE |